mm electrical logo

M.M. ELECTRICALS & ELECTRONICS

DPM (Digital panel meters)

Product at a glance

Easy to install and use, high in accuracy and alerts to act

The DPM series is a range of digital panel meters for reliable and accurate measurement of both AC parameters (voltage, current, frequency, power, power factor and energy) and DC parameters (voltage and current) for industrial and commercial applications. DPM provides true RMS measurement for AC parameters.

Application

  • HV and MV switchgear panels
  • Power control centre (PCC) panels
  • Motor control centre (MCC) panels
  • LV dist

Benefits

  • Clear display, can be easily read even from a distance
  • Quick and easy installation with unique pass through concept for current termination (with minimal burden)
  • Common product for different panel applications (with field configurability)
  • Wide-range aux input makes it suitable for a variety of installation scenarios
  • User-friendly touch-sense keys for easy display access
  • Compact size to optimise use of panel space

Features

  • LED and LCD display product ranges
  • Reliable and accurate measurement
  • User configurable alert thresholds for various parameters
  • Unique pass through mechanism for current termination
  • Wide-range AC / DC auxiliary power supply
  • High level of protection degree
  • Display of minimum and maximum values
  • Touch-sense keys for ease of use – display access & configuration
  • Current and power demand monitoring
  • Available in three different panel cut-outs
  • Field programmable – CT / PT commissioning etc
  • Password-protected setup mode
  • Auto unit adjustment for voltage, current, power and energy

Product range

Phase AC Single-phase AC Three-phase
Display Single line LED Single line LCD Single line LED Three line

LED

Three line

LCD

Dimensions 96 x 96 96 x 48 96 x 96 96 x 48 72 x 72 96 x 96 96 x 48 96 x 96 96 x 96
DPM96 DPM48 DPM96 DPM48 DPM72 DPM96 DPM48 DPM96 DPM96
Parameter
AC current I100 I150 I300 I310 I360
AC voltage V100 V150 V300 V310 V360
Active power W100 W150 W310 W360
Reactive power R310 R360
Power factor P310 P360
Frequency F100 F150
Active energy with Modbus E300
Voltage – Current – Frequency meter M310 M360
DC measurement
DC voltage V200
DC current I200

Specification

Electrical Single-phase Three-phase
LED LCD LED LCD
Connection type 1 Phase 2 Wire (AC applications) 1 Phase 2 Wire / 3 Phase 3 Wire /

3 Phase 4 Wire

Voltmeter
Measuring voltage range 5 V to 500 V
Nominal voltage range 57.5 V to 240 V (phase to neutral) | 100 V to 415 V (phase to phase)
Over voltage 150% Un continous
Ammeter
Measuring current range 50 mA to 6 A
Nominal current range (In) 1 A or 5 A
Overload 150% In continuous
Short time over current 120 A for 1 sec
Active power Measuring voltage range: 5 V to 500 V Voltage (Un): 57.5 V to 240 V (phase to neutral), 100 V to 415 V ( phase to phase) Measuring voltage range: 20 V to 500 V Voltage (Un): 57.5 V to 240 V (phase to neutral), 100 V to 415 V ( phase to phase)
Measuring current range: 50 mA to 6 A, Current (In): 1 A or 5 A
Reactive power As for active power
Power factor 0.1 lag – Unity – 0.1 lead (for In and Un)
Frequency range 45 to 65 Hz
DC Voltmeter 0 to 250 Vdc

Tolerance: +20% of Vdc

DC Ammeter Configurable external shunt value:

-150 mV … 0 … +150 mV

Tolerance: +20% for shunt input

Auxiliary supply range 40 to 300 V AC / DC
Accuracy class
Voltage, current ±0.5% FS
Frequency ±0.1 Hz
Active power ±0.5% FS (at unity PF)
Reactive power ±0.5% FS
Power factor ±0.005
Energy Class 1.0

(acc. to IEC 62053-21)

DC Voltmeter ±0.2% FS
DC Ammeter ±0.2% FS
Temperature coefficient Voltage, current: 0.05% / ºC
Burden
Voltage circuit
Current circuit 1 A:
Auxiliary supply
Auxiliary supply (with -RS485) variant only)

For more details click here.

DPM (Digital panel meters)

DPM (Digital panel meters)

CALL FOR PRICE

Product at a glance

Easy to install and use, high in accuracy and alerts to act

The DPM series is a range of digital panel meters for reliable and accurate measurement of both AC parameters (voltage, current, frequency, power, power factor and energy) and DC parameters (voltage and current) for industrial and commercial applications. DPM provides true RMS measurement for AC parameters.

Application

  • HV and MV switchgear panels
  • Power control centre (PCC) panels
  • Motor control centre (MCC) panels
  • LV dist

Benefits

  • Clear display, can be easily read even from a distance
  • Quick and easy installation with unique pass through concept for current termination (with minimal burden)
  • Common product for different panel applications (with field configurability)
  • Wide-range aux input makes it suitable for a variety of installation scenarios
  • User-friendly touch-sense keys for easy display access
  • Compact size to optimise use of panel space

Features

  • LED and LCD display product ranges
  • Reliable and accurate measurement
  • User configurable alert thresholds for various parameters
  • Unique pass through mechanism for current termination
  • Wide-range AC / DC auxiliary power supply
  • High level of protection degree
  • Display of minimum and maximum values
  • Touch-sense keys for ease of use – display access & configuration
  • Current and power demand monitoring
  • Available in three different panel cut-outs
  • Field programmable – CT / PT commissioning etc
  • Password-protected setup mode
  • Auto unit adjustment for voltage, current, power and energy

Product range

Phase AC Single-phase AC Three-phase
Display Single line LED Single line LCD Single line LED Three line

LED

Three line

LCD

Dimensions 96 x 96 96 x 48 96 x 96 96 x 48 72 x 72 96 x 96 96 x 48 96 x 96 96 x 96
DPM96 DPM48 DPM96 DPM48 DPM72 DPM96 DPM48 DPM96 DPM96
Parameter
AC current I100 I150 I300 I310 I360
AC voltage V100 V150 V300 V310 V360
Active power W100 W150 W310 W360
Reactive power R310 R360
Power factor P310 P360
Frequency F100 F150
Active energy with Modbus E300
Voltage – Current – Frequency meter M310 M360
DC measurement
DC voltage V200
DC current I200

Specification

Electrical Single-phase Three-phase
LED LCD LED LCD
Connection type 1 Phase 2 Wire (AC applications) 1 Phase 2 Wire / 3 Phase 3 Wire /

3 Phase 4 Wire

Voltmeter
Measuring voltage range 5 V to 500 V
Nominal voltage range 57.5 V to 240 V (phase to neutral) | 100 V to 415 V (phase to phase)
Over voltage 150% Un continous
Ammeter
Measuring current range 50 mA to 6 A
Nominal current range (In) 1 A or 5 A
Overload 150% In continuous
Short time over current 120 A for 1 sec
Active power Measuring voltage range: 5 V to 500 V Voltage (Un): 57.5 V to 240 V (phase to neutral), 100 V to 415 V ( phase to phase) Measuring voltage range: 20 V to 500 V Voltage (Un): 57.5 V to 240 V (phase to neutral), 100 V to 415 V ( phase to phase)
Measuring current range: 50 mA to 6 A, Current (In): 1 A or 5 A
Reactive power As for active power
Power factor 0.1 lag – Unity – 0.1 lead (for In and Un)
Frequency range 45 to 65 Hz
DC Voltmeter 0 to 250 Vdc

Tolerance: +20% of Vdc

DC Ammeter Configurable external shunt value:

-150 mV … 0 … +150 mV

Tolerance: +20% for shunt input

Auxiliary supply range 40 to 300 V AC / DC
Accuracy class
Voltage, current ±0.5% FS
Frequency ±0.1 Hz
Active power ±0.5% FS (at unity PF)
Reactive power ±0.5% FS
Power factor ±0.005
Energy Class 1.0

(acc. to IEC 62053-21)

DC Voltmeter ±0.2% FS
DC Ammeter ±0.2% FS
Temperature coefficient Voltage, current: 0.05% / ºC
Burden
Voltage circuit
Current circuit 1 A:
Auxiliary supply
Auxiliary supply (with -RS485) variant only)

For more details click here.

DPM (Digital panel meters)