M.M. ELECTRICALS & ELECTRONICS
- info@mmelectricalsindia.com
- Mon-Sat 09:30 A.M to 06:30P.M
The Elite 500 series includes devices with advanced power monitoring capabilities, which can be used for standalone device monitoring and power quality analysis as part of BMS, process industrial controls and SCADA systems. it also offer data logging, control IOs and modular communication with multiple protocols for third party system integration. Based on the application, Elite 500 allows customers to select conventional type CT or Rogowski coil input, which can be directly connected to the meter without the need for any additional integrator.
Specification
Conventional | Rogowski | |
Electrical | ||
Connection type | Common product for 1P2W / 3P3W / 3P4W applications | |
Measurement voltage range | 35 V to 500 V (L-L) max, 20 V to 300 V (L-N) max | |
Measurement current range | 10mA – 6 A (configurable) | 5% Ipr -Ipr (Ipr -1000 A or 4000 A) |
Starting current range | 1mA | 1 A for 1000 A / 4 A for 4000 A |
Frequency | 50 / 60 Hz | |
Burden | Current circuit: < 0.2 VA/phase @ 1A & @ 5A Voltage circuit: < 0.2 VA/phase | |
Sampling rate | 156 samples / cycle / channel | |
Accuracy | ||
Energy | Class 0.2S / class 0.5S | Class 0.5S |
Voltage, Current, Power | 0.2% for measurement range | |
Frequency | ±0.05 Hz | |
Power factor | ±0.005 (0.5 lag to 0.5 lead) | |
Maximum withstand Voltage | 2 times of nominal voltage value for 1 Sec repeated 10 times at 10 second interval | |
Maximum withstand current | 1.2 times of Ib continuously | – |
Short time over current | 20 times Imax for 1 second, 10 x Imax for 3 sec., 7 x Imax for 10 sec. | – |
Overload (continuous) | 1.5 times of Ib (Up to 7.5A) (only measurement) |
– |
Standard | IEC 62052-11, IEC 62053-22, IEC 62053-24, IEC61557-12, IEC 62053-31, IEC 60529, IEC 61010-1, IEC 61010-2-030, IEC 61326-1, IS14697, CE, UKCA IEC 61850-6, 7-1, 7-2, 7-3, 7-4, 8-1, (as per edition 1 and 2) |
|
Environmental | ||
Ingress protection | IP 54 (front fascia); IP20 (at terminals), IP 65 with gasket (Optional) | |
Insulation | 3.5 kV RMS 50 Hz, 1 minute | |
Impulse withstand | 6.4 kV | |
Operating temperature | -10°C to + 60°C | |
Storage temperature | -25°C to + 70°C | |
Temperature coefficient | 0.1% / °C | |
Mechanical dimension | 96 x 96 x 57.6 mm (± 0.5 mm) (H x W x D) | |
Weight | 365 g | |
Software | – Two data loggers: Primary data logger Logging of up to 20 energy channels values, with integration period 5, 15, 30 & 60 minutes ~15000 parameter-days capacity at 30-minute interval Secondary data logger Logging of up to 20 instantaneous values with integration period 1, 2, 5, 10, 15 & 30 minutes ~35000 parameter-days capacity at 30-minute interval – Configurable parameters:
Up to 31st individual harmonic component measurement |
|
Features | ||
Power supply | Range: 48-300VDC or 85-300VAC | |
Burden | Base product: <3W, < 6.5VA at 240V AC. With all modules: <6.5W, <16VA | |
Display | TFT for graphical and analytics (3.5 inch) | |
Size: 53 x 70 mm (H x W), 320×240 pixels. Pixel size: 0.22 mm² | ||
Battery | Battery for RTC backup | |
Inputs and Outputs | 1 relay output, 1 fixed pulse output, 2 configurable pulse inputs / outputs
|
|
Communication | ||
RS485 port | Protocol: Modbus RTU Baud rate: 1200 – 38400 bps, parity- none, even, odd |
|
Ethernet port | Ethernet over RJ-45, 10 / 100 Mbit / s, SNTP time sync Optional Modbus TCP / IP, Modbus Gateway, BACnet IP, ProfiNET, IEC61850 |
|
Software support | Configview (for configuration / reading), Optional eWatch 100 / eWatch Online |
For more details click here.
The Elite 500 series includes devices with advanced power monitoring capabilities, which can be used for standalone device monitoring and power quality analysis as part of BMS, process industrial controls and SCADA systems. it also offer data logging, control IOs and modular communication with multiple protocols for third party system integration. Based on the application, Elite 500 allows customers to select conventional type CT or Rogowski coil input, which can be directly connected to the meter without the need for any additional integrator.
Specification
Conventional | Rogowski | |
Electrical | ||
Connection type | Common product for 1P2W / 3P3W / 3P4W applications | |
Measurement voltage range | 35 V to 500 V (L-L) max, 20 V to 300 V (L-N) max | |
Measurement current range | 10mA – 6 A (configurable) | 5% Ipr -Ipr (Ipr -1000 A or 4000 A) |
Starting current range | 1mA | 1 A for 1000 A / 4 A for 4000 A |
Frequency | 50 / 60 Hz | |
Burden | Current circuit: < 0.2 VA/phase @ 1A & @ 5A Voltage circuit: < 0.2 VA/phase | |
Sampling rate | 156 samples / cycle / channel | |
Accuracy | ||
Energy | Class 0.2S / class 0.5S | Class 0.5S |
Voltage, Current, Power | 0.2% for measurement range | |
Frequency | ±0.05 Hz | |
Power factor | ±0.005 (0.5 lag to 0.5 lead) | |
Maximum withstand Voltage | 2 times of nominal voltage value for 1 Sec repeated 10 times at 10 second interval | |
Maximum withstand current | 1.2 times of Ib continuously | – |
Short time over current | 20 times Imax for 1 second, 10 x Imax for 3 sec., 7 x Imax for 10 sec. | – |
Overload (continuous) | 1.5 times of Ib (Up to 7.5A) (only measurement) |
– |
Standard | IEC 62052-11, IEC 62053-22, IEC 62053-24, IEC61557-12, IEC 62053-31, IEC 60529, IEC 61010-1, IEC 61010-2-030, IEC 61326-1, IS14697, CE, UKCA IEC 61850-6, 7-1, 7-2, 7-3, 7-4, 8-1, (as per edition 1 and 2) |
|
Environmental | ||
Ingress protection | IP 54 (front fascia); IP20 (at terminals), IP 65 with gasket (Optional) | |
Insulation | 3.5 kV RMS 50 Hz, 1 minute | |
Impulse withstand | 6.4 kV | |
Operating temperature | -10°C to + 60°C | |
Storage temperature | -25°C to + 70°C | |
Temperature coefficient | 0.1% / °C | |
Mechanical dimension | 96 x 96 x 57.6 mm (± 0.5 mm) (H x W x D) | |
Weight | 365 g | |
Software | – Two data loggers: Primary data logger Logging of up to 20 energy channels values, with integration period 5, 15, 30 & 60 minutes ~15000 parameter-days capacity at 30-minute interval Secondary data logger Logging of up to 20 instantaneous values with integration period 1, 2, 5, 10, 15 & 30 minutes ~35000 parameter-days capacity at 30-minute interval – Configurable parameters:
Up to 31st individual harmonic component measurement |
|
Features | ||
Power supply | Range: 48-300VDC or 85-300VAC | |
Burden | Base product: <3W, < 6.5VA at 240V AC. With all modules: <6.5W, <16VA | |
Display | TFT for graphical and analytics (3.5 inch) | |
Size: 53 x 70 mm (H x W), 320×240 pixels. Pixel size: 0.22 mm² | ||
Battery | Battery for RTC backup | |
Inputs and Outputs | 1 relay output, 1 fixed pulse output, 2 configurable pulse inputs / outputs
|
|
Communication | ||
RS485 port | Protocol: Modbus RTU Baud rate: 1200 – 38400 bps, parity- none, even, odd |
|
Ethernet port | Ethernet over RJ-45, 10 / 100 Mbit / s, SNTP time sync Optional Modbus TCP / IP, Modbus Gateway, BACnet IP, ProfiNET, IEC61850 |
|
Software support | Configview (for configuration / reading), Optional eWatch 100 / eWatch Online |
For more details click here.
M M Electricals India has been serving their clients since 1998. A Delhi (India) based company established by Manish Ranjan. We are authorised dealer of Cadel Technology Pvt. Ltd. – Banglore, Secure Meters Ltd. – Udaypur, AE Automatic Electric – Mumbai..
Register Office Address – D-197. U.G. Floor, Milan Appertment C.R. Road,Laxmi Nagar, Vikas Marg, New Delhi-110092
Head Office Address – Office No.-10,Plot No.-48, Ground Floor, Hasanpur, New Delhi-110092
Ware House – Plot No. 04, Hasanpur, IP Extension, New Delhi-110092
Copyright © 2021-M.M. ELECTRICALS & ELECTRONICS- All rights reserved